GTQ-trax30

GTQ-trax30 1. Flexible Multi-Sensor Selection for Diverse Detection Needs: Equipped with three mainstream sensor types—electrochemical, semiconductor, and PID—each with a service life of 1-3 years. Choose based on requirements to comprehensively cover real-time toxic gas monitoring needs across industrial scenarios. 2. High-precision rapid response with stable, reliable data: T90 response time of 20-25 seconds, repeatability ±2%. Achieves stable operation after 3 minutes of warm-up. Low zero and sensitivity drift (≤±2% FS/6 months, <3% FS/6 months) ensures minimal data deviation during long-term use. 3. User-Friendly Operation & Industrial Compatibility: Features a Chinese LCD display with 4 LED status indicators for clear visibility. Supports wide voltage input (DC 18-30V) and meets GB16838 electromagnetic standards for interference resistance, ensuring stable operation in complex industrial environments. 4. Multi-functional Output + Flexible Interfaces for Enhanced Expandability: Supports 4-20mA/ISBUS output (interfaces with PLC/DCS) and 2 relays for alarm device linkage. Features default 3/4-inch NPT ports with optional multi-specifications to accommodate diverse installation and control requirements. 5. High Protection for Harsh Environments, Ensures Compliance and Safety: IP66 protection + die-cast aluminum/316 stainless steel housing, suitable for -20°C to 50°C, 15%-95% RH (non-condensing) environments; meets multiple standards and explosion-proof certifications for safe use in hazardous areas.

Application

It can be widely used in the city gas transmission and distribution pipeline, oil, petrochemical industry refineries, chemical plants, metallurgical industry, power industry and other places that may produce gas leakage.

  • City Lifeline
  • City Lifeline
  • City Lifeline
  • City Lifeline
  •  Core Sensor Performance Lifespan - Electrochemical Sensor: > 2 years (suitable for toxic gas detection) - Semiconductor Sensor: > 3 years (suitable for toxic gas detection) - PID Sensor: > 1 year (usage under specified conditions) 
  • Response Time & Repeatability
  • - Response Time (T90): Typically 20–25 seconds (time to reach 90% of target concentration) - Repeatability: Typical ±2% (deviation range for repeated detection of same-concentration gas)  Preheating Time & Drift
  • - Preheating Time: 3 minutes (to enter stable detection state after power-on) - Zero Drift: ±2% FS per half-year (max baseline deviation without target gas; FS = Full Scale) - Sensitivity Drift: < 3% FS per half-year (max sensitivity change to target gas)
  •   Display Function 
  • - LCD Display: Chinese interface, real-time display of gas concentration & operation menu - LED Indicators: 4 indicators (Alarm 1, Alarm 2, Fault, Power)
  • Operating Voltage : DC24V
  • Voltage Range: DC18-30V (stable operation within 18-30V DC; rated voltage = 24V DC) Operating Current :
  • - Electrochemical Sensor: 20mA (monitoring), 40mA (maximum) - Semiconductor Sensor: 60mA (monitoring), 80mA (maximum) - PID Sensor: 40mA (monitoring), 70mA (maximum) Electromagnetic Compatibility:
  • Complies with national standard GB16838 (resists electromagnetic interference for stable data) 
  • Signal Output :
  • - 4-20mA current output (analog signal, connectable to PLC/DCS for remote concentration transmission) - ISBUS three-wire bus (digital bus, supports multi-device networking & data interaction)
  • Relay Output : - Alarm 1 Relay: Normally open contact, rated load 3A@125VAC/30VDC (controls alarms/exhaust when triggered) - Alarm 2 Relay: Normally open contact, rated load 3A@125VAC/30VDC (hierarchical control via different thresholds) 
  • Electrical Interface : - Default: 2 x 3/4" NPT female ports (for cable access/sealing) - Optional: M20×1.5, G1/2, G3/4 (specify when ordering) | | Physical & Environmental Parameters | Housing Material - Standard: Aluminum casting (steel-free) with epoxy resin baked finish (anti-corrosion/anti-rust) - Optional: 316 stainless steel (for highly corrosive harsh environments) Weight - Standard Housing: 1.5 kg - Stainless Steel Housing: 3.5 kg (for stainless steel detectors) Operating Environment 
  • - Operating Humidity (Toxic Gas): 15%~95% RH (non-condensing; condensation affects performance) - Operating Temperature (Toxic Gas): -20°C~50°C (normal operation range) - Protection Rating: IP66 (dustproof, resists strong water splashes; suitable for outdoor/humid areas) | | Compliance & Certifications | Standards & Certifications | 1. Industry Standard: HG/T3987-2007 (gas detection alarm standard) 2. Explosion-Proof Standard: GB3836-2021 (electrical equipment for explosive atmospheres) 3. Metrology Certifications: National Manufacturing Metrology Instrument Licensing Regulations, CPA Metrology Certification (China Metrology Accreditation, meets verification requirements) 4. Explosion-Proof Certification: Qualified for explosive hazardous areas 